CONCRETE FLOOR SLAB - Style 1

Copyright Kneebone & Beretta Group

TABLE 1.

Continuous slab over 2 spans
supporting timber framed walls only

SLAB SPAN SLAB THICKNESS
2100mm maximum 100mm minimum
3500mm maximum 125mm minimum
4500mm maximum 150mm minimum
5500mm maximum 170mm minimum

 

TABLE 2.

Continuous slab over 2 spans
supporting brick walls

SLAB SPAN SLAB THICKNESS
3000mm maximum 125mm minimum
4000mm maximum 150mm minimum
4800mm maximum 175mm minimum